Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
TIMETAL 6-4 PropertiesTIMETarchived copyTitanium · Yield strength: typical, plate (>0.187 in), annealed, 0.2% offsetTitanium · Ultimate tensile strength: typical, plate, annealedTitanium · Elongation at break: typical, in 2 in., plate annealedTitanium · Density: nominalTitanium · Poisson's ratio: mean of TIMET measurementsTitanium · Melting point: melting rangeTitanium · Max service temperature: upper recommended use temperature
2
SUMIKASUPER LCP Technical Note, Version 04 (2023)Sumitomo Chemicalarchived copyPlastic LCP GF30 · Ultimate tensile strength: tensile strength (ISO 527)Plastic LCP GF30 · Flexural strength: typical (ISO 178)Plastic LCP GF30 · Elongation at break: tensile elongation (ISO 527)Plastic LCP GF30 · Young's modulus (stiffness): tensile modulus (ISO 527)Plastic LCP GF30 · Density: typicalPlastic LCP GF30 · Thermal conductivity: hot disk (ISO 22007-2), temperature not statedPlastic LCP GF30 · Thermal expansion: flow direction (MD), mean 50-150 °CPlastic LCP GF30 · Specific heat: ASTM E1269, temperature not statedPlastic LCP GF30 · Max service temperature: HDT 1.8 MPa (ISO 75)
3
TIMETAL 6-4 Data SheetTIMETarchived copyTitanium · Young's modulus (stiffness): typical range, 20 °CTitanium · Thermal conductivity: typical, 20 °C, mill annealedTitanium · Thermal expansion: typical, mean 0-100 °CTitanium · Specific heat: typical, 20 °C
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
Questions
Mechanical
Is Plastic LCP GF30 stronger than Titanium?
Titanium is stronger: its yield strength is 885 MPa against tensile strength 115 MPa for Plastic LCP GF30 (7.7x).
Which is lighter, Plastic LCP GF30 or Titanium?
Plastic LCP GF30 is lighter: 1,610 kg/m³ against 4,430 kg/m³ for Titanium.
Which is stiffer, Plastic LCP GF30 or Titanium?
Titanium is stiffer: Young's modulus 115 GPa against 11.5 GPa for Plastic LCP GF30, so the same part in Titanium deflects less under the same load.
Which is lighter for the same job, Plastic LCP GF30 or Titanium?
For the same stiffness or strength: Plastic LCP GF30 is lighter for a stiff panel or plate; Titanium is lighter for a stiff rod or tie (tension), stiff beam (bending), strong rod or tie, strong beam.
Part that must be
Plastic LCP GF30
Titanium
Stiff rod or tie (tension)
3.62x heavier
lighter
Stiff beam (bending)
15% heavier
lighter
Stiff panel or plate
lighter
28% heavier
Strong rod or tie
2.8x heavier
lighter
Strong beam
42% heavier
lighter
Strong panel or plate
about equal
about equal
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Plastic LCP GF30 or Titanium?
Titanium stretches further before it breaks: 16% elongation at break against 1.5% for Plastic LCP GF30.
Thermal
Which conducts heat better, Plastic LCP GF30 or Titanium?
Titanium conducts heat better: 6.6 W/m·K against 0.5 W/m·K for Plastic LCP GF30.
Which expands less with temperature?
Titanium expands less: 9 µm/m·K against 20 µm/m·K for Plastic LCP GF30.