Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
SUMIKASUPER LCP Technical Note, Version 04 (2023)Sumitomo Chemicalarchived copyPlastic LCP GF30 · Ultimate tensile strength: tensile strength (ISO 527)Plastic LCP GF30 · Flexural strength: typical (ISO 178)Plastic LCP GF30 · Elongation at break: tensile elongation (ISO 527)Plastic LCP GF30 · Young's modulus (stiffness): tensile modulus (ISO 527)Plastic LCP GF30 · Density: typicalPlastic LCP GF30 · Thermal conductivity: hot disk (ISO 22007-2), temperature not statedPlastic LCP GF30 · Thermal expansion: flow direction (MD), mean 50-150 °CPlastic LCP GF30 · Specific heat: ASTM E1269, temperature not statedPlastic LCP GF30 · Max service temperature: HDT 1.8 MPa (ISO 75)
3
Wieland-K32 (Cu-ETP, C11000) Data SheetWielandarchived copyCopper C110 · Poisson's ratio: reference value at room temperature (Wieland-K32 = Cu-ETP = C11000, rolled products)
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
Questions
Mechanical
Is Copper C110 stronger than Plastic LCP GF30?
Plastic LCP GF30 is stronger: its tensile strength is 115 MPa against yield strength 69 MPa for Copper C110 (1.67x).
Which is lighter, Copper C110 or Plastic LCP GF30?
Plastic LCP GF30 is lighter: 1,610 kg/m³ against 8,913 kg/m³ for Copper C110.
Which is stiffer, Copper C110 or Plastic LCP GF30?
Copper C110 is stiffer: Young's modulus 117 GPa against 11.5 GPa for Plastic LCP GF30, so the same part in Copper C110 deflects less under the same load.
Which is lighter for the same job, Copper C110 or Plastic LCP GF30?
For the same stiffness or strength: Copper C110 is lighter for a stiff rod or tie (tension); Plastic LCP GF30 is lighter for a stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
Copper C110
Plastic LCP GF30
Stiff rod or tie (tension)
lighter
1.84x heavier
Stiff beam (bending)
1.73x heavier
lighter
Stiff panel or plate
2.55x heavier
lighter
Strong rod or tie
9.23x heavier
lighter
Strong beam
7.78x heavier
lighter
Strong panel or plate
7.15x heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Copper C110 or Plastic LCP GF30?
Copper C110 stretches further before it breaks: 55% elongation at break against 1.5% for Plastic LCP GF30.
Thermal
Which conducts heat better, Copper C110 or Plastic LCP GF30?
Copper C110 conducts heat better: 391 W/m·K against 0.5 W/m·K for Plastic LCP GF30.
Which expands less with temperature?