Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA sample part to run stress or thermal on, free in your browser
Sources4 documents: Bambu Lab, Isola, Park Electrochemical (Nelco), INEOS Styrolution
FDM ASA
Bambu Lab ASA, TDS V3.0, printed specimens X-Y; nozzle 260 °C, bed 80 °C, 200 mm/s, 100% infill; annealed and dried 80 °C for 12 h before testing.
PCB Laminate FR-4
Isola 370HR FR-4 laminate (Polyclad PCL-FR-370HR, 180 C Tg multifunctional epoxy, E-glass fabric), copper removed; Isola data sheet Revision C, last updated April 15, 2021. Woven-glass laminate: the sheet gives in-plane values per weave direction (length / cross) and the Z-axis CTE separately; the solver is isotropic per material.
370HR Laminate and Prepreg Data SheetIsolaarchived copyPCB Laminate FR-4 · Ultimate tensile strength: typical, in-plane: cross direction .. length direction (ASTM D3039)PCB Laminate FR-4 · Flexural strength: typical: cross direction .. length direction (IPC-TM-650 2.4.4B)PCB Laminate FR-4 · Young's modulus (stiffness): typical, in-plane: cross direction .. length direction (ASTM D790-15e2)PCB Laminate FR-4 · Poisson's ratio: typical, in-plane: cross direction .. length directionPCB Laminate FR-4 · Thermal conductivity: typical (ASTM E1952); direction not stated by the sheetPCB Laminate FR-4 · Thermal expansion: typical, in-plane X/Y-axis, below Tg (IPC-TM-650 2.4.24C)PCB Laminate FR-4 · Glass transition: typical, DSC (IPC-TM-650 2.4.25C)PCB Laminate FR-4 · Max service temperature: UL Relative Thermal Index (UL 796)
3
N4000-6 Laminate Data Sheet (2006)Park Electrochemical (Nelco)archived copyPCB Laminate FR-4 · Density: typical, 50% resin content; another FR-4 producer: Park Nelco N4000-6 (high-Tg multifunctional epoxy), not Isola 370HRPCB Laminate FR-4 · Specific heat: typical (ASTM E1461); another FR-4 producer: Park Nelco N4000-6 (high-Tg multifunctional epoxy), not Isola 370HR
4
Luran S 777K (ASA) Product Data SheetINEOS StyrolutionFDM ASA · Thermal conductivity: base material: INEOS Styrolution Luran S 777K injection-molding ASA, typicalFDM ASA · Thermal expansion: base material: INEOS Styrolution Luran S 777K injection-molding ASA, range
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
FDM ASA is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is FDM ASA stronger than PCB Laminate FR-4?
PCB Laminate FR-4 is stronger: its tensile strength is 315 MPa against 37 MPa for FDM ASA (8.52x).
Which is lighter, FDM ASA or PCB Laminate FR-4?
FDM ASA is lighter: 1,050 kg/m³ against 1,920 kg/m³ for PCB Laminate FR-4.
Which is stiffer, FDM ASA or PCB Laminate FR-4?
PCB Laminate FR-4 is stiffer: Young's modulus 23.9 GPa against 2.45 GPa for FDM ASA, so the same part in PCB Laminate FR-4 deflects less under the same load.
Which is lighter for the same job, FDM ASA or PCB Laminate FR-4?
For the same stiffness or strength: PCB Laminate FR-4 is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
FDM ASA
PCB Laminate FR-4
Stiff rod or tie (tension)
5.33x heavier
lighter
Stiff beam (bending)
1.71x heavier
lighter
Stiff panel or plate
17% heavier
lighter
Strong rod or tie
4.66x heavier
lighter
Strong beam
2.28x heavier
lighter
Strong panel or plate
1.6x heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Thermal
Which conducts heat better, FDM ASA or PCB Laminate FR-4?
PCB Laminate FR-4 conducts heat better: 0.4 W/m·K against 0.17 W/m·K for FDM ASA.
Which expands less with temperature?
PCB Laminate FR-4 expands less: 13.5 µm/m·K against 95 µm/m·K for FDM ASA.