Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sources5 documents: Cleveland-Cliffs, Formlabs, National Institute of Standards and Technology
Iron
Cleveland-Cliffs / AK Steel ARMCO Pure Iron Product Data Bulletin (07/2022): Table 1 typical physical properties, Table 2 typical mechanical properties after SRA/recrystallization anneal.
SLA Resin Standard
Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
1
ARMCO Pure Iron Product Data Bulletin (2022)Cleveland-Cliffsarchived copyIron · Yield strength: typical (0.2% YS), hot rolled + SRA/recrystallization annealIron · Ultimate tensile strength: typical, SRA/recrystallization annealIron · Elongation at break: typical, gauge 4D0Iron · Young's modulus (stiffness): typical, after SRA/recrystallization annealIron · Density: typicalIron · Thermal conductivity: typical at 20 °CIron · Thermal expansion: mean, 20-399 °CIron · Specific heat: typicalIron · Melting point: typical
2
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copySLA Resin Standard · Ultimate tensile strength: typicalSLA Resin Standard · Flexural strength: typicalSLA Resin Standard · Elongation at break: typicalSLA Resin Standard · Young's modulus (stiffness): typicalSLA Resin Standard · Max service temperature: HDT 1.8 MPa
3
Clear Resin V5 Technical Data Sheet (web edition)FormlabsSLA Resin Standard · Density: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
4
Elastic Properties of Metals and Alloys, I. Iron, Nickel, and Iron-Nickel Alloys, J. Phys. Chem. Ref. Data 2 (1973)National Institute of Standards and Technologyarchived copyIron · Poisson's ratio: NIST critically evaluated best value (polycrystalline iron)
5
Thermal Properties of Selected Formlabs SLA ResinsFormlabsSLA Resin Standard · Thermal conductivity: typical, post-cured, ASTM E1530SLA Resin Standard · Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831SLA Resin Standard · Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
SLA Resin Standard is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is Iron stronger than SLA Resin Standard?
Iron is stronger: its yield strength is 186 MPa against tensile strength 60 MPa for SLA Resin Standard (3.1x).
Which is lighter, Iron or SLA Resin Standard?
SLA Resin Standard is lighter: 1,210 kg/m³ against 7,860 kg/m³ for Iron.
Which is stiffer, Iron or SLA Resin Standard?
Iron is stiffer: Young's modulus 207 GPa against 2.75 GPa for SLA Resin Standard, so the same part in Iron deflects less under the same load.
Which is lighter for the same job, Iron or SLA Resin Standard?
For the same stiffness or strength: Iron is lighter for a stiff rod or tie (tension), stiff beam (bending); SLA Resin Standard is lighter for a stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
Iron
SLA Resin Standard
Stiff rod or tie (tension)
lighter
11.6x heavier
Stiff beam (bending)
lighter
34% heavier
Stiff panel or plate
1.54x heavier
lighter
Strong rod or tie
2.1x heavier
lighter
Strong beam
3.06x heavier
lighter
Strong panel or plate
3.69x heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Iron or SLA Resin Standard?
Iron stretches further before it breaks: 38% elongation at break against 8% for SLA Resin Standard.
Thermal
Which conducts heat better, Iron or SLA Resin Standard?
Iron conducts heat better: 73.2 W/m·K against 0.54 W/m·K for SLA Resin Standard.
Which expands less with temperature?
Iron expands less: 13.7 µm/m·K against 114 µm/m·K for SLA Resin Standard.