Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA sample part to run stress or thermal on, free in your browser
Sources6 documents: American Institute of Steel Construction, Isola, Park Electrochemical (Nelco), bauforumstahl (ArcelorMittal), Ovako
PCB Laminate FR-4
Isola 370HR FR-4 laminate (Polyclad PCL-FR-370HR, 180 C Tg multifunctional epoxy, E-glass fabric), copper removed; Isola data sheet Revision C, last updated April 15, 2021. Woven-glass laminate: the sheet gives in-plane values per weave direction (length / cross) and the Z-axis CTE separately; the solver is isotropic per material.
Steel A992
ASTM A992 W-shapes; Fy/Fu specified minimums from AISC publications (AISC 360-16 Commentary; Modern Steel Construction); elastic constants AISC 360; physical constants from the bauforumstahl structural-steel EPD, which names A992 among covered product standards.
1
Updating Standard Shape Material Properties Database for Design and ReliabilityAmerican Institute of Steel Constructionarchived copySteel A992 · Yield strength: typical: mean of 20,295 A992 flange mill-test coupons (1998 SSPC survey), as reported by AISCSteel A992 · Ultimate tensile strength: typical: mean of 20,295 A992 flange mill-test coupons (1998 SSPC survey)Steel A992 · Elongation at break: typical: mean of 24,847 A992 mill-test elongations, web and flange (1998 SSPC mill data), as reported by AISC
2
370HR Laminate and Prepreg Data SheetIsolaarchived copyPCB Laminate FR-4 · Ultimate tensile strength: typical, in-plane: cross direction .. length direction (ASTM D3039)PCB Laminate FR-4 · Flexural strength: typical: cross direction .. length direction (IPC-TM-650 2.4.4B)PCB Laminate FR-4 · Young's modulus (stiffness): typical, in-plane: cross direction .. length direction (ASTM D790-15e2)PCB Laminate FR-4 · Poisson's ratio: typical, in-plane: cross direction .. length directionPCB Laminate FR-4 · Thermal conductivity: typical (ASTM E1952); direction not stated by the sheetPCB Laminate FR-4 · Thermal expansion: typical, in-plane X/Y-axis, below Tg (IPC-TM-650 2.4.24C)PCB Laminate FR-4 · Glass transition: typical, DSC (IPC-TM-650 2.4.25C)PCB Laminate FR-4 · Max service temperature: UL Relative Thermal Index (UL 796)
3
ANSI/AISC 360-16 Specification for Structural Steel Buildings, with CommentaryAmerican Institute of Steel Constructionarchived copySteel A992 · Young's modulus (stiffness): design value (AISC 360-16)Steel A992 · Poisson's ratio: design value (AISC 360-16 Commentary)
4
N4000-6 Laminate Data Sheet (2006)Park Electrochemical (Nelco)archived copyPCB Laminate FR-4 · Density: typical, 50% resin content; another FR-4 producer: Park Nelco N4000-6 (high-Tg multifunctional epoxy), not Isola 370HRPCB Laminate FR-4 · Specific heat: typical (ASTM E1461); another FR-4 producer: Park Nelco N4000-6 (high-Tg multifunctional epoxy), not Isola 370HR
5
Environmental Product Declaration: Structural Steel Sections and Merchant Bars (2023)bauforumstahl (ArcelorMittal)archived copySteel A992 · Density: nominal (constructional data)Steel A992 · Thermal conductivity: nominal at 20 °CSteel A992 · Thermal expansion: nominal (constructional data, no temperature range stated)
6
S275JR Steel GradeOvakoSteel A992 · Specific heat: base material: EN S275JR unalloyed structural steel (the EN counterpart of A36), typical, 50/100 °C
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
Questions
Mechanical
Is PCB Laminate FR-4 stronger than Steel A992?
Steel A992 is stronger: its yield strength is 385 MPa against tensile strength 315 MPa for PCB Laminate FR-4 (22%).
Which is lighter, PCB Laminate FR-4 or Steel A992?
PCB Laminate FR-4 is lighter: 1,920 kg/m³ against 7,850 kg/m³ for Steel A992.
Which is stiffer, PCB Laminate FR-4 or Steel A992?
Steel A992 is stiffer: Young's modulus 200 GPa against 23.9 GPa for PCB Laminate FR-4, so the same part in Steel A992 deflects less under the same load.
Which is lighter for the same job, PCB Laminate FR-4 or Steel A992?
For the same stiffness or strength: PCB Laminate FR-4 is lighter for a stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate; Steel A992 is lighter for a stiff rod or tie (tension).
Part that must be
PCB Laminate FR-4
Steel A992
Stiff rod or tie (tension)
2.05x heavier
lighter
Stiff beam (bending)
lighter
41% heavier
Stiff panel or plate
lighter
2.01x heavier
Strong rod or tie
lighter
3.35x heavier
Strong beam
lighter
3.58x heavier
Strong panel or plate
lighter
3.7x heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Thermal
Which conducts heat better, PCB Laminate FR-4 or Steel A992?
Steel A992 conducts heat better: 48 W/m·K against 0.4 W/m·K for PCB Laminate FR-4.
Which expands less with temperature?
Steel A992 expands less: 12 µm/m·K against 13.5 µm/m·K for PCB Laminate FR-4.