Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sources5 documents: Carpenter Technology, Formlabs, U.S. Department of Defense
SLA Resin Standard
Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copySLA Resin Standard · Ultimate tensile strength: typicalSLA Resin Standard · Flexural strength: typicalSLA Resin Standard · Elongation at break: typicalSLA Resin Standard · Young's modulus (stiffness): typicalSLA Resin Standard · Max service temperature: HDT 1.8 MPa
3
MIL-HDBK-5J, Metallic Materials and Elements for Aerospace Vehicle Structures (2003)U.S. Department of DefenseSteel AISI 4340 · Young's modulus (stiffness): MIL-HDBK-5J design value (AISI 4340, quenched and tempered)Steel AISI 4340 · Poisson's ratio: MIL-HDBK-5J design value (AISI 4340, quenched and tempered)
4
Clear Resin V5 Technical Data Sheet (web edition)FormlabsSLA Resin Standard · Density: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
5
Thermal Properties of Selected Formlabs SLA ResinsFormlabsSLA Resin Standard · Thermal conductivity: typical, post-cured, ASTM E1530SLA Resin Standard · Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831SLA Resin Standard · Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
SLA Resin Standard is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is SLA Resin Standard stronger than Steel AISI 4340?
Steel AISI 4340 is stronger: its yield strength is 1,035 MPa against tensile strength 60 MPa for SLA Resin Standard (17.3x).
Which is lighter, SLA Resin Standard or Steel AISI 4340?
SLA Resin Standard is lighter: 1,210 kg/m³ against 7,840 kg/m³ for Steel AISI 4340.
Which is stiffer, SLA Resin Standard or Steel AISI 4340?
Steel AISI 4340 is stiffer: Young's modulus 200 GPa against 2.75 GPa for SLA Resin Standard, so the same part in Steel AISI 4340 deflects less under the same load.
Which is lighter for the same job, SLA Resin Standard or Steel AISI 4340?
For the same stiffness or strength: SLA Resin Standard is lighter for a stiff panel or plate, strong panel or plate; Steel AISI 4340 is lighter for a stiff rod or tie (tension), stiff beam (bending), strong rod or tie, strong beam.
Part that must be
SLA Resin Standard
Steel AISI 4340
Stiff rod or tie (tension)
11.2x heavier
lighter
Stiff beam (bending)
32% heavier
lighter
Stiff panel or plate
lighter
1.55x heavier
Strong rod or tie
2.66x heavier
lighter
Strong beam
3% heavier
lighter
Strong panel or plate
lighter
1.56x heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, SLA Resin Standard or Steel AISI 4340?
Steel AISI 4340 stretches further before it breaks: 18% elongation at break against 8% for SLA Resin Standard.
Thermal
Which conducts heat better, SLA Resin Standard or Steel AISI 4340?
Steel AISI 4340 conducts heat better: 37.5 W/m·K against 0.54 W/m·K for SLA Resin Standard.
Which expands less with temperature?
Steel AISI 4340 expands less: 11.3 µm/m·K against 114 µm/m·K for SLA Resin Standard.