Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copySLA Resin Standard · Ultimate tensile strength: typicalSLA Resin Standard · Flexural strength: typicalSLA Resin Standard · Elongation at break: typicalSLA Resin Standard · Young's modulus (stiffness): typicalSLA Resin Standard · Max service temperature: HDT 1.8 MPa
Clear Resin V5 Technical Data Sheet (web edition)FormlabsSLA Resin Standard · Density: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
5
Wieland-M30 (CuZn30, C26000) Data SheetWielandarchived copyBrass C260 · Poisson's ratio: reference value at room temperature (Wieland-M30 = CuZn30 = C26000, rolled products)
6
Thermal Properties of Selected Formlabs SLA ResinsFormlabsSLA Resin Standard · Thermal conductivity: typical, post-cured, ASTM E1530SLA Resin Standard · Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831SLA Resin Standard · Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
SLA Resin Standard is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is Brass C260 stronger than SLA Resin Standard?
Brass C260 is stronger: its yield strength is 345 MPa against tensile strength 60 MPa for SLA Resin Standard (5.75x).
Which is lighter, Brass C260 or SLA Resin Standard?
SLA Resin Standard is lighter: 1,210 kg/m³ against 8,525 kg/m³ for Brass C260.
Which is stiffer, Brass C260 or SLA Resin Standard?
Brass C260 is stiffer: Young's modulus 110 GPa against 2.75 GPa for SLA Resin Standard, so the same part in Brass C260 deflects less under the same load.
Which is lighter for the same job, Brass C260 or SLA Resin Standard?
For the same stiffness or strength: Brass C260 is lighter for a stiff rod or tie (tension); SLA Resin Standard is lighter for a stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
Brass C260
SLA Resin Standard
Stiff rod or tie (tension)
lighter
5.69x heavier
Stiff beam (bending)
11% heavier
lighter
Stiff panel or plate
2.06x heavier
lighter
Strong rod or tie
23% heavier
lighter
Strong beam
2.2x heavier
lighter
Strong panel or plate
2.94x heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Brass C260 or SLA Resin Standard?
Brass C260 stretches further before it breaks: 23% elongation at break against 8% for SLA Resin Standard.
Thermal
Which conducts heat better, Brass C260 or SLA Resin Standard?
Brass C260 conducts heat better: 121 W/m·K against 0.54 W/m·K for SLA Resin Standard.
Which expands less with temperature?
Brass C260 expands less: 20 µm/m·K against 114 µm/m·K for SLA Resin Standard.