Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sources3 documents: EOS GmbH, Formlabs, Cleveland-Cliffs
DMLS 17-4PH Stainless Steel
EOS StainlessSteel 17-4PH IndustryLine (powder 9011-0041), EOS M 290, 40 µm, default job 17-4PH_040_StainlessM291_100, as built, horizontal; ISO 6892 & ASTM E8M
SLA Resin Tough 2000
Formlabs Tough 2000 Resin V2 (FLTO2002), TDS Rev. 01 10/06/2025; printed on Form 4 at 100 µm, washed in Form Wash V2 10+5 min in >=99% IPA, post-cured 70 °C for 12 min in Form Cure V2. Orientation not stated.
1
EOS StainlessSteel 17-4PH IndustryLine Material Data Sheet, M 290EOS GmbHarchived copyDMLS 17-4PH Stainless Steel · Yield strength: mean, as built, horizontal (N=72)DMLS 17-4PH Stainless Steel · Ultimate tensile strength: mean, as built, horizontal (N=72)DMLS 17-4PH Stainless Steel · Elongation at break: mean at break, as built, horizontalDMLS 17-4PH Stainless Steel · Density: mean part density (ISO 3369)DMLS 17-4PH Stainless Steel · Thermal expansion: mean 25-100 °C, ASTM E228, AFTER atmospheric heat treatment (as-built value not published)
17-4 PH Stainless Steel Product Data Bulletin (2021)Cleveland-CliffsDMLS 17-4PH Stainless Steel · Young's modulus (stiffness): base material: wrought 17-4 PH, Condition H 900 (Cleveland-Cliffs)DMLS 17-4PH Stainless Steel · Poisson's ratio: base material: wrought 17-4 PH, all conditions (Cleveland-Cliffs)DMLS 17-4PH Stainless Steel · Thermal conductivity: base material: wrought 17-4 PH, Condition H 900, at 149 °C (Cleveland-Cliffs)DMLS 17-4PH Stainless Steel · Specific heat: base material: wrought 17-4 PH, Condition A, 0-100 °C (Cleveland-Cliffs)
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
DMLS 17-4PH Stainless Steel and SLA Resin Tough 2000 are 3D printed: their properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is DMLS 17-4PH Stainless Steel stronger than SLA Resin Tough 2000?
DMLS 17-4PH Stainless Steel is stronger: its yield strength is 861 MPa against 40.4 MPa for SLA Resin Tough 2000 (21.3x).
Which is lighter, DMLS 17-4PH Stainless Steel or SLA Resin Tough 2000?
SLA Resin Tough 2000 is lighter: 1,090 kg/m³ against 7,790 kg/m³ for DMLS 17-4PH Stainless Steel.
Which is stiffer, DMLS 17-4PH Stainless Steel or SLA Resin Tough 2000?
DMLS 17-4PH Stainless Steel is stiffer: Young's modulus 197 GPa against 1.8 GPa for SLA Resin Tough 2000, so the same part in DMLS 17-4PH Stainless Steel deflects less under the same load.
Which is lighter for the same job, DMLS 17-4PH Stainless Steel or SLA Resin Tough 2000?
For the same stiffness or strength: DMLS 17-4PH Stainless Steel is lighter for a stiff rod or tie (tension), stiff beam (bending), strong rod or tie, strong beam; SLA Resin Tough 2000 is lighter for a stiff panel or plate, strong panel or plate.
Part that must be
DMLS 17-4PH Stainless Steel
SLA Resin Tough 2000
Stiff rod or tie (tension)
lighter
15.3x heavier
Stiff beam (bending)
lighter
46% heavier
Stiff panel or plate
49% heavier
lighter
Strong rod or tie
lighter
2.98x heavier
Strong beam
lighter
8% heavier
Strong panel or plate
1.55x heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, DMLS 17-4PH Stainless Steel or SLA Resin Tough 2000?
SLA Resin Tough 2000 stretches further before it breaks: 79% elongation at break against 19.9% for DMLS 17-4PH Stainless Steel.
Thermal
Which expands less with temperature?
DMLS 17-4PH Stainless Steel expands less: 10.4 µm/m·K against 134 µm/m·K for SLA Resin Tough 2000.