Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sources6 documents: American Institute of Steel Construction, BASF Forward AM, bauforumstahl (ArcelorMittal), INEOS Styrolution, Ovako
FDM HIPS
BASF Forward AM (BASF 3D Printing Solutions) Ultrafuse HiPS, TDS v2.2 (13.11.2019), printed specimens, XY 'Flat'. Specimen print settings are not stated; recommended processing on the sheet: nozzle 240-260 °C, bed 100-120 °C, 40-80 mm/s. Product is discontinued (Forward AM product page) but the TDS is still served by Forward AM.
Steel A992
ASTM A992 W-shapes; Fy/Fu specified minimums from AISC publications (AISC 360-16 Commentary; Modern Steel Construction); elastic constants AISC 360; physical constants from the bauforumstahl structural-steel EPD, which names A992 among covered product standards.
1
Updating Standard Shape Material Properties Database for Design and ReliabilityAmerican Institute of Steel Constructionarchived copySteel A992 · Yield strength: typical: mean of 20,295 A992 flange mill-test coupons (1998 SSPC survey), as reported by AISCSteel A992 · Ultimate tensile strength: typical: mean of 20,295 A992 flange mill-test coupons (1998 SSPC survey)Steel A992 · Elongation at break: typical: mean of 24,847 A992 mill-test elongations, web and flange (1998 SSPC mill data), as reported by AISC
S275JR Steel GradeOvakoSteel A992 · Specific heat: base material: EN S275JR unalloyed structural steel (the EN counterpart of A36), typical, 50/100 °C
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
FDM HIPS is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is FDM HIPS stronger than Steel A992?
Steel A992 is stronger: its yield strength is 385 MPa against tensile strength 18.4 MPa for FDM HIPS (20.9x).
Which is lighter, FDM HIPS or Steel A992?
FDM HIPS is lighter: 1,023 kg/m³ against 7,850 kg/m³ for Steel A992.
Which is stiffer, FDM HIPS or Steel A992?
Steel A992 is stiffer: Young's modulus 200 GPa against 1.59 GPa for FDM HIPS, so the same part in Steel A992 deflects less under the same load.
Which is lighter for the same job, FDM HIPS or Steel A992?
For the same stiffness or strength: FDM HIPS is lighter for a stiff panel or plate, strong beam, strong panel or plate; Steel A992 is lighter for a stiff rod or tie (tension), stiff beam (bending), strong rod or tie.
Part that must be
FDM HIPS
Steel A992
Stiff rod or tie (tension)
16.4x heavier
lighter
Stiff beam (bending)
46% heavier
lighter
Stiff panel or plate
lighter
1.53x heavier
Strong rod or tie
2.73x heavier
lighter
Strong beam
lighter
1% heavier
Strong panel or plate
lighter
1.68x heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, FDM HIPS or Steel A992?
Steel A992 stretches further before it breaks: 24.2% elongation at break against 1.4% for FDM HIPS.
Thermal
Which conducts heat better, FDM HIPS or Steel A992?
Steel A992 conducts heat better: 48 W/m·K against 0.17 W/m·K for FDM HIPS.
Which expands less with temperature?
Steel A992 expands less: 12 µm/m·K against 80 µm/m·K for FDM HIPS.