Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Bambu Lab PAHT-CF, TDS V3.0, printed specimens X-Y, dry state; nozzle 290 °C, bed 100 °C, 100 mm/s, 100% infill; annealed and dried 80 °C for 12 h before testing.
Plastic UHMWPE
Celanese GUR 4120 (avg. molecular weight 4.7x10^6 g/mol), typical values on compression-molded specimens; CTE and thermal conductivity from Celanese's generic UHMWPE guide (grade not named)
1
GUR UHMW-PE Overview (GUR-015)CelanesePlastic UHMWPE · Yield strength: typical, tensile stress at yield ISO 527, 50 mm/minPlastic UHMWPE · Ultimate tensile strength: typical, tensile stress at break ISO 527, 50 mm/minPlastic UHMWPE · Elongation at break: typical, nominal elongation at break ISO 527Plastic UHMWPE · Young's modulus (stiffness): typical, tensile modulus ISO 527, 1 mm/minPlastic UHMWPE · Density: typicalPlastic UHMWPE · Melting point: DSC 10 K/minPlastic UHMWPE · Max service temperature: recommended max constant operating temperature
GUR UHMW-PE Polymer Guide (GUR-003)Celanesearchived copyPlastic UHMWPE · Thermal conductivity: typical, unfilled (narrative value, generic Celanese UHMWPE)Plastic UHMWPE · Thermal expansion: typical, 20 to 100 °C (generic Celanese UHMWPE)
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
FDM PAHT-CF is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is FDM PAHT-CF stronger than Plastic UHMWPE?
FDM PAHT-CF is stronger: its tensile strength is 92 MPa against yield strength 20 MPa for Plastic UHMWPE (4.6x).
Which is lighter, FDM PAHT-CF or Plastic UHMWPE?
Plastic UHMWPE is lighter: 930 kg/m³ against 1,060 kg/m³ for FDM PAHT-CF.
Which is stiffer, FDM PAHT-CF or Plastic UHMWPE?
FDM PAHT-CF is stiffer: Young's modulus 3.86 GPa against 0.66 GPa for Plastic UHMWPE, so the same part in FDM PAHT-CF deflects less under the same load.
Which is lighter for the same job, FDM PAHT-CF or Plastic UHMWPE?
For the same stiffness or strength: FDM PAHT-CF is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
FDM PAHT-CF
Plastic UHMWPE
Stiff rod or tie (tension)
lighter
5.13x heavier
Stiff beam (bending)
lighter
2.12x heavier
Stiff panel or plate
lighter
1.58x heavier
Strong rod or tie
lighter
4.04x heavier
Strong beam
lighter
2.43x heavier
Strong panel or plate
lighter
1.88x heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, FDM PAHT-CF or Plastic UHMWPE?
Plastic UHMWPE stretches further before it breaks: 465% elongation at break against 8.4% for FDM PAHT-CF.