Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sources6 documents: Magnesium Elektron, American Institute of Steel Construction, bauforumstahl (ArcelorMittal), U.S. Department of Defense, Ovako
Magnesium AZ91D
ELEKTRON AZ91D magnesium die-casting alloy, as cast; Magnesium Elektron datasheet 475 (7/01), typical properties; Poisson from MIL-HDBK-5J for AZ91C castings.
Steel A992
ASTM A992 W-shapes; Fy/Fu specified minimums from AISC publications (AISC 360-16 Commentary; Modern Steel Construction); elastic constants AISC 360; physical constants from the bauforumstahl structural-steel EPD, which names A992 among covered product standards.
1
Elektron Die Casting Alloys (Datasheet 475)Magnesium Elektronarchived copyMagnesium AZ91D · Yield strength: typical, 0.2% tensile yield, ambient temperatureMagnesium AZ91D · Ultimate tensile strength: typical, ambient temperatureMagnesium AZ91D · Elongation at break: typical, ambient temperatureMagnesium AZ91D · Young's modulus (stiffness): typicalMagnesium AZ91D · Density: typicalMagnesium AZ91D · Thermal conductivity: typicalMagnesium AZ91D · Thermal expansion: typical, temperature range not statedMagnesium AZ91D · Specific heat: typicalMagnesium AZ91D · Melting point: melting range
2
Updating Standard Shape Material Properties Database for Design and ReliabilityAmerican Institute of Steel Constructionarchived copySteel A992 · Yield strength: typical: mean of 20,295 A992 flange mill-test coupons (1998 SSPC survey), as reported by AISCSteel A992 · Ultimate tensile strength: typical: mean of 20,295 A992 flange mill-test coupons (1998 SSPC survey)Steel A992 · Elongation at break: typical: mean of 24,847 A992 mill-test elongations, web and flange (1998 SSPC mill data), as reported by AISC
3
ANSI/AISC 360-16 Specification for Structural Steel Buildings, with CommentaryAmerican Institute of Steel Constructionarchived copySteel A992 · Young's modulus (stiffness): design value (AISC 360-16)Steel A992 · Poisson's ratio: design value (AISC 360-16 Commentary)
4
Environmental Product Declaration: Structural Steel Sections and Merchant Bars (2023)bauforumstahl (ArcelorMittal)archived copySteel A992 · Density: nominal (constructional data)Steel A992 · Thermal conductivity: nominal at 20 °CSteel A992 · Thermal expansion: nominal (constructional data, no temperature range stated)
5
MIL-HDBK-5J, Metallic Materials and Elements for Aerospace Vehicle Structures (2003)U.S. Department of DefenseMagnesium AZ91D · Poisson's ratio: base material: AZ91C casting (MIL-HDBK-5J handbook physical constant)
6
S275JR Steel GradeOvakoSteel A992 · Specific heat: base material: EN S275JR unalloyed structural steel (the EN counterpart of A36), typical, 50/100 °C
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
Questions
Mechanical
Is Magnesium AZ91D stronger than Steel A992?
Steel A992 is stronger: its yield strength is 385 MPa against 150 MPa for Magnesium AZ91D (2.57x).
Which is lighter, Magnesium AZ91D or Steel A992?
Magnesium AZ91D is lighter: 1,810 kg/m³ against 7,850 kg/m³ for Steel A992.
Which is stiffer, Magnesium AZ91D or Steel A992?
Steel A992 is stiffer: Young's modulus 200 GPa against 45 GPa for Magnesium AZ91D, so the same part in Steel A992 deflects less under the same load.
Which is lighter for the same job, Magnesium AZ91D or Steel A992?
For the same stiffness or strength: Magnesium AZ91D is lighter for a stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate; Steel A992 is lighter for a stiff rod or tie (tension).
Part that must be
Magnesium AZ91D
Steel A992
Stiff rod or tie (tension)
2% heavier
lighter
Stiff beam (bending)
lighter
2.06x heavier
Stiff panel or plate
lighter
2.64x heavier
Strong rod or tie
lighter
1.69x heavier
Strong beam
lighter
2.31x heavier
Strong panel or plate
lighter
2.71x heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Magnesium AZ91D or Steel A992?
Steel A992 stretches further before it breaks: 24.2% elongation at break against 3% for Magnesium AZ91D.
Thermal
Which conducts heat better, Magnesium AZ91D or Steel A992?
Magnesium AZ91D conducts heat better: 72 W/m·K against 48 W/m·K for Steel A992.
Which expands less with temperature?
Steel A992 expands less: 12 µm/m·K against 25 µm/m·K for Magnesium AZ91D.