Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sumitomo Chemical SUMIKASUPER LCP E6006L (30% glass fibre; high strength, low shrinkage); SUMIKASUPER LCP Technical Note, Version 04 / Nov. 2023, typical values.
SLA Resin Standard
Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
1
SUMIKASUPER LCP Technical Note, Version 04 (2023)Sumitomo Chemicalarchived copyPlastic LCP GF30 · Ultimate tensile strength: tensile strength (ISO 527)Plastic LCP GF30 · Flexural strength: typical (ISO 178)Plastic LCP GF30 · Elongation at break: tensile elongation (ISO 527)Plastic LCP GF30 · Young's modulus (stiffness): tensile modulus (ISO 527)Plastic LCP GF30 · Density: typicalPlastic LCP GF30 · Thermal conductivity: hot disk (ISO 22007-2), temperature not statedPlastic LCP GF30 · Thermal expansion: flow direction (MD), mean 50-150 °CPlastic LCP GF30 · Specific heat: ASTM E1269, temperature not statedPlastic LCP GF30 · Max service temperature: HDT 1.8 MPa (ISO 75)
2
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copySLA Resin Standard · Ultimate tensile strength: typicalSLA Resin Standard · Flexural strength: typicalSLA Resin Standard · Elongation at break: typicalSLA Resin Standard · Young's modulus (stiffness): typicalSLA Resin Standard · Max service temperature: HDT 1.8 MPa
3
Clear Resin V5 Technical Data Sheet (web edition)FormlabsSLA Resin Standard · Density: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
4
Thermal Properties of Selected Formlabs SLA ResinsFormlabsSLA Resin Standard · Thermal conductivity: typical, post-cured, ASTM E1530SLA Resin Standard · Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831SLA Resin Standard · Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
SLA Resin Standard is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is Plastic LCP GF30 stronger than SLA Resin Standard?
Plastic LCP GF30 is stronger: its tensile strength is 115 MPa against 60 MPa for SLA Resin Standard (1.92x).
Which is lighter, Plastic LCP GF30 or SLA Resin Standard?
SLA Resin Standard is lighter: 1,210 kg/m³ against 1,610 kg/m³ for Plastic LCP GF30.
Which is stiffer, Plastic LCP GF30 or SLA Resin Standard?
Plastic LCP GF30 is stiffer: Young's modulus 11.5 GPa against 2.75 GPa for SLA Resin Standard, so the same part in Plastic LCP GF30 deflects less under the same load.
Which is lighter for the same job, Plastic LCP GF30 or SLA Resin Standard?
For the same stiffness or strength: Plastic LCP GF30 is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
Plastic LCP GF30
SLA Resin Standard
Stiff rod or tie (tension)
lighter
3.14x heavier
Stiff beam (bending)
lighter
1.54x heavier
Stiff panel or plate
lighter
21% heavier
Strong rod or tie
lighter
44% heavier
Strong beam
lighter
16% heavier
Strong panel or plate
lighter
4% heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Plastic LCP GF30 or SLA Resin Standard?
SLA Resin Standard stretches further before it breaks: 8% elongation at break against 1.5% for Plastic LCP GF30.
Thermal
Which handles higher temperatures, Plastic LCP GF30 or SLA Resin Standard?
Plastic LCP GF30 does: 288 °C against 59 °C for SLA Resin Standard.
Which conducts heat better, Plastic LCP GF30 or SLA Resin Standard?
SLA Resin Standard conducts heat better: 0.54 W/m·K against 0.5 W/m·K for Plastic LCP GF30.
Which expands less with temperature?
Plastic LCP GF30 expands less: 20 µm/m·K against 114 µm/m·K for SLA Resin Standard.