Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Bambu Lab PAHT-CF, TDS V3.0, printed specimens X-Y, dry state; nozzle 290 °C, bed 100 °C, 100 mm/s, 100% infill; annealed and dried 80 °C for 12 h before testing.
SLS PA12 Nylon
EOS PA 2200 (PA12) Material Data Sheet, process parameter 'Balance' at 120 µm layer thickness, X orientation, dry (conditioned values not given). Live MDS status 04.10.2026, last changed 10.09.2026; PDF via ?topdf=... link on the same page.
PA 2200 Balance Material Data SheetEOS GmbHSLS PA12 Nylon · Ultimate tensile strength: typicalSLS PA12 Nylon · Elongation at break: typicalSLS PA12 Nylon · Young's modulus (stiffness): typicalSLS PA12 Nylon · Density: typicalSLS PA12 Nylon · Melting point: typicalSLS PA12 Nylon · Max service temperature: HDT 1.8 MPa, X orientation
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
FDM PAHT-CF and SLS PA12 Nylon are 3D printed: their properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is FDM PAHT-CF stronger than SLS PA12 Nylon?
FDM PAHT-CF is stronger: its tensile strength is 92 MPa against 48 MPa for SLS PA12 Nylon (1.92x).
Which is lighter, FDM PAHT-CF or SLS PA12 Nylon?
SLS PA12 Nylon is lighter: 930 kg/m³ against 1,060 kg/m³ for FDM PAHT-CF.
Which is stiffer, FDM PAHT-CF or SLS PA12 Nylon?
FDM PAHT-CF is stiffer: Young's modulus 3.86 GPa against 1.65 GPa for SLS PA12 Nylon, so the same part in FDM PAHT-CF deflects less under the same load.
Which is lighter for the same job, FDM PAHT-CF or SLS PA12 Nylon?
For the same stiffness or strength: FDM PAHT-CF is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
FDM PAHT-CF
SLS PA12 Nylon
Stiff rod or tie (tension)
lighter
2.05x heavier
Stiff beam (bending)
lighter
34% heavier
Stiff panel or plate
lighter
16% heavier
Strong rod or tie
lighter
1.68x heavier
Strong beam
lighter
35% heavier
Strong panel or plate
lighter
21% heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, FDM PAHT-CF or SLS PA12 Nylon?
SLS PA12 Nylon stretches further before it breaks: 18% elongation at break against 8.4% for FDM PAHT-CF.
Thermal
Which handles higher temperatures, FDM PAHT-CF or SLS PA12 Nylon?
FDM PAHT-CF does: 170 °C against 64 °C for SLS PA12 Nylon.