Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Celanese Fortron 1140L4 (PPS, 40% glass fibre), injection moulding; FORTRON PPS Short-Term Properties Guide (PPS-012, 2016); thermal conductivity and Poisson for 40% glass-reinforced Fortron from the Fortron PPS Design Manual (PPS-050, 2013).
SLA Resin Standard
Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copySLA Resin Standard · Ultimate tensile strength: typicalSLA Resin Standard · Flexural strength: typicalSLA Resin Standard · Elongation at break: typicalSLA Resin Standard · Young's modulus (stiffness): typicalSLA Resin Standard · Max service temperature: HDT 1.8 MPa
3
Clear Resin V5 Technical Data Sheet (web edition)FormlabsSLA Resin Standard · Density: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
Thermal Properties of Selected Formlabs SLA ResinsFormlabsSLA Resin Standard · Thermal conductivity: typical, post-cured, ASTM E1530SLA Resin Standard · Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831SLA Resin Standard · Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
SLA Resin Standard is 3D printed: its properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is Plastic PPS GF40 stronger than SLA Resin Standard?
Plastic PPS GF40 is stronger: its tensile strength is 195 MPa against 60 MPa for SLA Resin Standard (3.25x).
Which is lighter, Plastic PPS GF40 or SLA Resin Standard?
SLA Resin Standard is lighter: 1,210 kg/m³ against 1,650 kg/m³ for Plastic PPS GF40.
Which is stiffer, Plastic PPS GF40 or SLA Resin Standard?
Plastic PPS GF40 is stiffer: Young's modulus 14.7 GPa against 2.75 GPa for SLA Resin Standard, so the same part in Plastic PPS GF40 deflects less under the same load.
Which is lighter for the same job, Plastic PPS GF40 or SLA Resin Standard?
For the same stiffness or strength: Plastic PPS GF40 is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
Plastic PPS GF40
SLA Resin Standard
Stiff rod or tie (tension)
lighter
3.92x heavier
Stiff beam (bending)
lighter
1.7x heavier
Stiff panel or plate
lighter
28% heavier
Strong rod or tie
lighter
2.38x heavier
Strong beam
lighter
1.61x heavier
Strong panel or plate
lighter
32% heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, Plastic PPS GF40 or SLA Resin Standard?
SLA Resin Standard stretches further before it breaks: 8% elongation at break against 1.9% for Plastic PPS GF40.
Thermal
Which handles higher temperatures, Plastic PPS GF40 or SLA Resin Standard?
Plastic PPS GF40 does: 270 °C against 59 °C for SLA Resin Standard, both HDT 1.8 MPa.
Which conducts heat better, Plastic PPS GF40 or SLA Resin Standard?
SLA Resin Standard conducts heat better: 0.54 W/m·K against 0.2 W/m·K for Plastic PPS GF40.
Which expands less with temperature?
Plastic PPS GF40 expands less: 12 µm/m·K against 114 µm/m·K for SLA Resin Standard.