Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
SLS PA12 Nylon
EOS PA 2200 (PA12) Material Data Sheet, process parameter 'Balance' at 120 µm layer thickness, X orientation, dry (conditioned values not given). Live MDS status 04.10.2026, last changed 10.09.2026; PDF via ?topdf=... link on the same page.
1
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copySLA Resin Standard · Ultimate tensile strength: typicalSLA Resin Standard · Flexural strength: typicalSLA Resin Standard · Elongation at break: typicalSLA Resin Standard · Young's modulus (stiffness): typicalSLA Resin Standard · Max service temperature: HDT 1.8 MPa
2
PA 2200 Balance Material Data SheetEOS GmbHSLS PA12 Nylon · Ultimate tensile strength: typicalSLS PA12 Nylon · Elongation at break: typicalSLS PA12 Nylon · Young's modulus (stiffness): typicalSLS PA12 Nylon · Density: typicalSLS PA12 Nylon · Melting point: typicalSLS PA12 Nylon · Max service temperature: HDT 1.8 MPa, X orientation
3
Clear Resin V5 Technical Data Sheet (web edition)FormlabsSLA Resin Standard · Density: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
4
Thermal Properties of Selected Formlabs SLA ResinsFormlabsSLA Resin Standard · Thermal conductivity: typical, post-cured, ASTM E1530SLA Resin Standard · Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831SLA Resin Standard · Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
SLA Resin Standard and SLS PA12 Nylon are 3D printed: their properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is SLA Resin Standard stronger than SLS PA12 Nylon?
SLA Resin Standard is stronger: its tensile strength is 60 MPa against 48 MPa for SLS PA12 Nylon (25%).
Which is lighter, SLA Resin Standard or SLS PA12 Nylon?
SLS PA12 Nylon is lighter: 930 kg/m³ against 1,210 kg/m³ for SLA Resin Standard.
Which is stiffer, SLA Resin Standard or SLS PA12 Nylon?
SLA Resin Standard is stiffer: Young's modulus 2.75 GPa against 1.65 GPa for SLS PA12 Nylon, so the same part in SLA Resin Standard deflects less under the same load.
Which is lighter for the same job, SLA Resin Standard or SLS PA12 Nylon?
For the same stiffness or strength: SLA Resin Standard is lighter for a stiff rod or tie (tension); SLS PA12 Nylon is lighter for a stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
SLA Resin Standard
SLS PA12 Nylon
Stiff rod or tie (tension)
lighter
28% heavier
Stiff beam (bending)
about equal
about equal
Stiff panel or plate
10% heavier
lighter
Strong rod or tie
4% heavier
lighter
Strong beam
12% heavier
lighter
Strong panel or plate
16% heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, SLA Resin Standard or SLS PA12 Nylon?
SLS PA12 Nylon stretches further before it breaks: 18% elongation at break against 8% for SLA Resin Standard.